Seismic Aluminum Infill Flooring System - No Bump Blockout Application (SFP with Infill /SFPw with Infill)
Seismic Aluminum Infill Flooring Expansion Joint System features a cover plate that stays centered over openings before, during and after a seismic event with the use of the centering bar. Heavy pedestrian traffic requirements are met while maintaining a smooth transition, limited sight line, and no bump transition.
Features
- Seismic Technology
- Horizontal and Vertical Thermal Movement
- Seismic Movement with Lateral Shear
- No Bump System with Minimal Sight Line
Specifications
Model | SFP/SFPw |
Material | 6063-T5 Aluminum, Meets ASTM B221 6061-T6 Aluminum, Meets ASTM B209 5052 H32 Aluminum, Meets ASTM B209 |
Finish | Mill |
Infill Depth | 1/8", 1/4", and 3/8" |
Movement | Thermal: Horizontal and Vertical Seismic: Lateral Shear |
Mounting | Blockout |
Joint Size | 2-12" |
Length | 10 Linear Feet |
Application | Interior |
Load | Pedestrian and Light Cart |
Installation | Floor |
Options | Moisture barrier, Fire barrier, Additional Materials, Sizes and Finishes available upon request |
Warranty | 1 year |
Order Guide
Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.
PART NUMBER | APPLICATION | JOINT SIZE at mean T°F |
SYSTEM WIDTH | INFILL HEIGHT | TOTAL MOVEMENT |
---|---|---|---|---|---|
EJN-SFP-200-125, -250, OR -375 | Floor-to-Floor | 2" (51mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 2" (51mm) |
EJN-SFP-400-125, -250, OR -375 | Floor-to-Floor | 4" (102mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 4" (102mm) |
EJN-SFP-600-125, -250, OR -375 | Floor-to-Floor | 6" (152mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 6" (152mm) |
EJN-SFP-800-125, -250, OR -375 | Floor-to-Floor | 8" (203mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 8" (203mm) |
EJN-SFP-1000-125, -250, OR -375 | Floor-to-Floor | 10" (254mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 10" (254mm) |
EJN-SFP-1200-125, -250, OR -375 | Floor-to-Floor | 12" (305mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 12" (305mm) |
EJN-SFP-200W-125, -250, OR -375 | Floor-to-Wall Corner | 2" (51mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 1" (25mm) |
EJN-SFP-400W-125, -250, OR -375 | Floor-to-Wall Corner | 4" (102mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 2" (51mm) |
EJN-SFP-600W-125, -250, OR -375 | Floor-to-Wall Corner | 6" (152mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 3" (76mm) |
EJN-SFP-800W-125, -250, OR -375 | Floor-to-Wall Corner | 8" (203mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 4" (102mm) |
EJN-SFP-1000W-125, -250, OR -375 | Floor-to-Wall Corner | 10" (254mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 5" (127mm) |
EJN-SFP-1200W-125, -250, OR -375 | Floor-to-Wall Corner | 12" (305mm) | Varies, See Shop Drawing | .125” (3mm), .250” (6mm), or .375” (10mm) | 6" (152mm) |
WARRANTY
NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.
Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.
For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.
Videos
Coming soon.Description | Model | Shop Drawing | CAD | Revit/BIM | Data Sheet | 3-Part Specs | LEED | Installation | Warranty |
---|---|---|---|---|---|---|---|---|---|
Floor-to-Floor | EJN-SFP-200-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-200-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-200-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-400-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-400-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-400-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-600-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-600-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-600-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-800-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-800-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-800-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1000-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1000-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1000-375 | DWG | |||||||
Floor-to-Wall-Corner | EJN-SFP-1200-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1200-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1200-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-200w-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-200w-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-200w-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-400w-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-400w-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-400w-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-600w-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-600w-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-600w-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-800w-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-800w-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-800w-375 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1000w-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1000w-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1000w-375 | DWG | |||||||
Floor-to-Wall-Corner | EJN-SFP-1200w-125 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1200w-250 | DWG | |||||||
Floor-to-Floor | EJN-SFP-1200w-375 | DWG |