Seismic Aluminum Infill Flooring Expansion Joint System features a cover plate that stays centered over openings before, during and after a seismic event with the use of the centering bar. Heavy pedestrian traffic requirements are met while maintaining a smooth transition, limited sight line, and no bump transition.

Features

  • Seismic Technology
  • Horizontal and Vertical Thermal Movement
  • Seismic Movement with Lateral Shear
  • No Bump System with Minimal Sight Line

Specifications

Model SFP/SFPw
Material 6063-T5 Aluminum, Meets ASTM B221
6061-T6 Aluminum, Meets ASTM B209
5052 H32 Aluminum, Meets ASTM B209
Finish Mill
Infill Depth 1/8", 1/4", and 3/8"
Movement Thermal: Horizontal and Vertical
Seismic: Lateral Shear
Mounting Blockout
Joint Size 2-12"
Length 10 Linear Feet
Application Interior
Load Pedestrian and Light Cart
Installation Floor
Options Moisture barrier, Fire barrier, Additional Materials, Sizes and Finishes available upon request
Warranty 1 year

Order Guide

Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.

PART NUMBER APPLICATION JOINT SIZE
at mean T°F
SYSTEM WIDTH INFILL HEIGHT TOTAL
MOVEMENT
EJN-SFP-200-125, -250, OR -375 Floor-to-Floor 2" (51mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 2" (51mm)
EJN-SFP-400-125, -250, OR -375 Floor-to-Floor 4" (102mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 4" (102mm)
EJN-SFP-600-125, -250, OR -375 Floor-to-Floor 6" (152mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 6" (152mm)
EJN-SFP-800-125, -250, OR -375 Floor-to-Floor 8" (203mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 8" (203mm)
EJN-SFP-1000-125, -250, OR -375 Floor-to-Floor 10" (254mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 10" (254mm)
EJN-SFP-1200-125, -250, OR -375 Floor-to-Floor 12" (305mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 12" (305mm)
EJN-SFP-200W-125, -250, OR -375 Floor-to-Wall Corner 2" (51mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 1" (25mm)
EJN-SFP-400W-125, -250, OR -375 Floor-to-Wall Corner 4" (102mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 2" (51mm)
EJN-SFP-600W-125, -250, OR -375 Floor-to-Wall Corner 6" (152mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 3" (76mm)
EJN-SFP-800W-125, -250, OR -375 Floor-to-Wall Corner 8" (203mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 4" (102mm)
EJN-SFP-1000W-125, -250, OR -375 Floor-to-Wall Corner 10" (254mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 5" (127mm)
EJN-SFP-1200W-125, -250, OR -375 Floor-to-Wall Corner 12" (305mm) Varies, See Shop Drawing .125” (3mm), .250” (6mm), or .375” (10mm) 6" (152mm)

WARRANTY

NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.

Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.


For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.

Warranty Support

Videos

Coming soon.
Coming soon.


Description Model Shop Drawing CAD Revit/BIM Data Sheet 3-Part Specs LEED Installation Warranty
Floor-to-Floor EJN-SFP-200-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-200-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-200-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-400-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-400-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-400-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-600-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-600-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-600-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-800-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-800-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-800-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1000-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1000-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1000-375 PDF DWG PDF PDF PDF
Floor-to-Wall-Corner EJN-SFP-1200-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1200-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1200-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-200w-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-200w-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-200w-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-400w-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-400w-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-400w-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-600w-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-600w-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-600w-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-800w-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-800w-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-800w-375 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1000w-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1000w-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1000w-375 PDF DWG PDF PDF PDF
Floor-to-Wall-Corner EJN-SFP-1200w-125 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1200w-250 PDF DWG PDF PDF PDF
Floor-to-Floor EJN-SFP-1200w-375 PDF DWG PDF PDF PDF