Seismic Aluminum Roof System - Curb Application (RJS/RJSw)
Description
This Architectural Roof System is designed for seismic and thermal movement and handles ice and snow loads. The integral weather seals and moisture barriers keep outside elements from penetrating the structural opening and interior areas.
Features
- Weather Resistant
- Architectural Elegance
- Horizontal and Vertical Thermal Movement
- Seismic Movement with Lateral Shear
- Coordinating Corners
Specifications
Model | RJS/RJSw |
Material | Aluminum 6061 |
Finish | Mill |
Movement | Thermal: Horizontal and Vertical Seismic: Lateral Shear |
Mounting | Surface |
Joint Size | 2 inches to 12 inches |
Length | 10 Linear Feet |
Installation | Roof |
Options | Fire barrier, Additional Materials, Sizes and Finishes available upon request |
Warranty | 1 year |
Order Guide
Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.
PART NUMBER | APPLICATION | JOINT SIZE at mean T°F |
EXPOSED SIGHT LINE |
TOTAL MOVEMENT |
---|---|---|---|---|
EJN-RJS-200 | Roof-to-Roof | 2" (51mm) | 7" (178mm) | 2" (51mm) |
EJN-RJS-400 | Roof-to-Roof | 4" (102mm) | 10" (255mm) | 4" (102mm) |
EJN-RJS-600 | Roof-to-Roof | 6" (152mm) | 12" (305mm) | 6" (152mm) |
EJN-RJS-800 | Roof-to-Roof | 8" (203mm) | 14" (356mm) | 8" (203mm) |
EJN-RJS-1000 | Roof-to-Roof | 10" (254mm) | 17" (432mm) | 10" (254mm) |
EJN-RJS-1200 | Roof-to-Roof | 12" (305mm) | 20" (508mm) | 12" (305mm) |
EJN-RJS-200w | Roof-to-Wall Corner | 2" (51mm) | 4.5" (114mm) | 1" (25mm) |
EJN-RJS-400w | Roof-to-Wall Corner | 4" (102mm) | 7" (178mm) | 2" (51mm) |
EJN-RJS-600w | Roof-to-Wall Corner | 6" (152mm) | 9" (228mm) | 3" (76mm) |
EJN-RJS-800w | Roof-to-Wall Corner | 8" (203mm) | 11" (280mm) | 4" (102mm) |
EJN-RJS-1000w | Roof-to-Wall Corner | 10" (254mm) | 13.5" (343mm) | 5" (127mm) |
EJN-RJS-1200w | Roof-to-Wall Corner | 12" (305mm) | 16" (406mm) | 6" (152mm) |
WARRANTY
NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.
Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.
For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.
Videos
Coming soon.Description | Model | Shop Drawing | CAD | Revit/BIM | Data Sheet | 3-Part Specs | LEED | Installation | Warranty |
---|---|---|---|---|---|---|---|---|---|
Roof-to-Roof | EJN-RJS-200 | DWG | LINK | WORD | |||||
Roof-to-Roof | EJN-RJS-400 | DWG | LINK | WORD | |||||
Roof-to-Roof | EJN-RJS-600 | DWG | LINK | WORD | |||||
Roof-to-Roof | EJN-RJS-800 | DWG | LINK | WORD | |||||
Roof-to-Roof | EJN-RJS-1000 | DWG | LINK | WORD | |||||
Roof-to-Roof | EJN-RJS-1200 | DWG | LINK | WORD | |||||
Roof-to-Wall Corner | EJN-RJS-200w | DWG | LINK | WORD | |||||
Roof-to-Wall Corner | EJN-RJS-400w | DWG | LINK | WORD | |||||
Roof-to-Wall Corner | EJN-RJS-600w | DWG | LINK | WORD | |||||
Roof-to-Wall Corner | EJN-RJS-800w | DWG | LINK | WORD | |||||
Roof-to-Wall Corner | EJN-RJS-1000w | DWG | LINK | WORD | |||||
Roof-to-Wall Corner | EJN-RJS-1200w | DWG | LINK | WORD |