Elastomeric Corridor Flooring System - Blockout Application (LCF/w)
Description
This Elastomeric System is built to last. The system’s extruded aluminum base is installed in a concrete blockout channel and backfilled in. Integrated into the system is a colored Santoprene seal that expands and compresses with horizontal movement.
Features
- Continuous Sight Line
- Thermal Movement
- Pedestrian and Light Cart Traffic
- 4 Complementary Seal Colors
- Blockout Installation
- Coordinating Corners
- ADA Compliant
Specifications
Model | LCF/w |
Material | 6063-T5 Aluminum with Santoprene Seal |
Finish | Mill |
Movement | Thermal: Horizontal |
Mounting | Blockout |
Joint Size | 1 inch to 3 inches |
Length | 10 Linear Feet |
Load | Pedestrian and Light Cart |
Installation | Floor |
Options | Moisture barrier, Fire barrier and additional materials, sizes and finishes upon request |
Warranty | 1 year |
Colors | Beige |
White |
Gray |
Black |
Order Guide
Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.
PART NUMBER | APPLICATION | JOINT SIZE at mean T°F |
EXPOSED SITE LINE |
TOTAL MOVEMENT |
---|---|---|---|---|
EJN-LCF-100 | Floor-to-Floor | 1" (25mm) | 1" (25mm) | .5" (13mm) |
EJN-LCF-200 | Floor-to-Floor | 2" (51mm) | 2" (51mm) | 1" (25mm) |
EJN-LCF-300 | Floor-to-Floor | 3" (76mm) | 3" (76mm) | 1.2" (30mm) |
EJN-LCF-100w | Floor-to-Wall | 1" (25mm) | 1" (25mm) | .5" (13mm) |
EJN-LCF-200w | Floor-to-Wall | 2" (51mm) | 2" (51mm) | 1" (25mm) |
EJN-LCF-300w | Floor-to-Wall | 3" (76mm) | 3" (76mm) | 1.2" (30mm) |
WARRANTY
NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.
Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.
For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.
Videos
Coming soon.Description | Model | Shop Drawing | CAD | Revit/BIM | Data Sheet | 3-Part Specs | LEED | Installation | Warranty |
---|---|---|---|---|---|---|---|---|---|
Floor to Floor | EJN-LCF-100 | DWG | LINK | WORD | |||||
Floor to Floor | EJN-LCF-200 | DWG | LINK | WORD | |||||
Floor to Floor | EJN-LCF-300 | DWG | LINK | WORD | |||||
Floor to Wall | EJN-LCF-100w | DWG | LINK | WORD | |||||
Floor to Wall | EJN-LCF-200w | DWG | LINK | WORD | |||||
Floor to Wall | EJN-LCF-300w | DWG | LINK | WORD |