1-, 2-, and 3-Hour Rated Seismic Pre-Compressed Vertical Foam System (FES1/FES2/FES3)
Description
1-, 2-, and 3-Hour Rated Seismic Pre-Compressed Vertical Foam System (FES1/FES2/FES3) is a silicone bellow system designed with a fire-retardant impregnated foam. It is watertight, fire-rated, and has a dual sided primary seal for both new and retrofit structural expansion joints in wall applications.
Features
- Up to 3-Hour Horizontal Fire Rated
- UL Listed
- Multi-Functional
- Sound Attenuating
- Non-Invasive Anchoring
Specifications
Model | FES1 / FES2 / FES3 |
Material | Foam with Silicone Bellows |
Sizes | 1/2 inch to 6 inches 1 Hour: 1/2 inch to 4 inches 2 and 3 Hours: 1/2 inch to 6 inches Additional sizes available in 1/4-inch increments from 1 to 6 inches |
Length | 6.56 linear feet |
Application | Interior or Exterior |
Installation | Wall |
Certifications | UL 2079 ASTM E1966, E119, E1399, E90 and C518 |
Options | Terminations, Transitions, Additional Sizes, Single-Sided, Uncoated and Pick-Resistant Coatings available upon request |
Movement | Standard: +/-50% (Total 100%) Also available in +/- 25% (Total 50%) |
Warranty | 1 year |
Colors | Adobe Tan |
Aluminum Stone |
Buff |
Anodized Aluminum |
Black |
Bronze |
Champagne |
Charcoal |
Dark Bronze |
Dusty Rose |
Gray |
Ivory |
|
Light Bronze |
Limestone |
Precast White |
Rustic Brick |
Sandstone |
Off White |
|
White |
Order Guide
Use the table below to guide specification of available options. The part number components are indicated in BOLD ORANGE text.
PART NUMBER | JOINT SIZE at mean T° F |
TOTAL MOVEMENT |
---|---|---|
EJN-FES1-050 | 1/2" (12mm) | 4" (102mm) |
EJN-FES1-075 | 3/4" (19mm) | 4" (102mm) |
EJN-FES1-100 | 1" (25mm) | 4" (102mm) |
EJN-FES1-200 | 2" (51mm) | 4" (102mm) |
EJN-FES1-300 | 3" (76mm) | 4" (102mm) |
EJN-FES1-400 | 4" (102mm) | 4" (102mm) |
EJN-FES2-050 | 1/2" (12mm) | 4" (102mm) |
EJN-FES2-075 | 3/4" (19mm) | 4" (102mm) |
EJN-FES2-100 | 1" (25mm) | 4" (102mm) |
EJN-FES2-200 | 2" (51mm) | 4" (102mm) |
EJN-FES2-300 | 3" (76mm) | 4" (102mm) |
EJN-FES2-400 | 4" (102mm) | 4" (102mm) |
EJN-FES2-500 | 5" (127mm) | 4" (102mm) |
EJN-FES2-600 | 6" (152mm) | 4" (102mm) |
EJN-FES3-050 | 1/2" (12mm) | 4" (102mm) |
EJN-FES3-075 | 3/4" (19mm) | 4" (102mm) |
EJN-FES3-100 | 1" (25mm) | 4" (102mm) |
EJN-FES3-200 | 2" (51mm) | 4" (102mm) |
EJN-FES3-300 | 3" (76mm) | 4" (102mm) |
EJN-FES3-400 | 4" (102mm) | 4" (102mm) |
EJN-FES3-500 | 5" (127mm) | 4" (102mm) |
EJN-FES3-600 | 6" (152mm) | 4" (102mm) |
Standard Movement of +/-50% (Total 100%), Also Available in +/-25% (Total 50%)
Additional sizes available in 1/4" increments from 1" and larger.
WARRANTY
NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.
Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.
For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.
Videos
Coming soon.Description | Model | Shop Drawing | CAD | Revit/BIM | Data Sheet | 3-Part Specs | LEED | Installation | Warranty |
---|---|---|---|---|---|---|---|---|---|
1-Hour Fire-Rated Wall |
EJN-FES1-050 | DWG | WORD | ||||||
1-Hour Fire-Rated Wall |
EJN-FES1-075 | DWG | WORD | ||||||
1-Hour Fire-Rated Wall |
EJN-FES1-100 | DWG | WORD | ||||||
1-Hour Fire-Rated Wall |
EJN-FES1-200 | DWG | WORD | ||||||
1-Hour Fire-Rated Wall |
EJN-FES1-300 | DWG | WORD | ||||||
1-Hour Fire-Rated Wall |
EJN-FES1-400 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-050 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-075 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-100 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-200 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-300 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-400 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-500 | DWG | WORD | ||||||
2-Hour Fire-Rated Wall |
EJN-FES2-600 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-050 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-075 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-100 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-200 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-300 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-400 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-500 | DWG | WORD | ||||||
3-Hour Fire-Rated Wall |
EJN-FES3-600 | DWG | WORD |