1-, 2-, and 3-Hour Rated Seismic Pre-Compressed Vertical Foam System (FES1/FES2/FES3) is a silicone bellow system designed with a fire-retardant impregnated foam. It is watertight, fire-rated, and has a dual sided primary seal for both new and retrofit structural expansion joints in wall applications.

Features

  • Up to 3-Hour Horizontal Fire Rated
  • UL Listed
  • Multi-Functional
  • Sound Attenuating
  • Non-Invasive Anchoring
WH-ETL Test reports can be accessed on the UL website by clicking the logo. You may also contact Nystrom for the report.




Specifications

Model FES1 / FES2 / FES3
Material Foam with Silicone Bellows
Sizes 1/2 inch to 6 inches
1 Hour: 1/2 inch to 4 inches
2 and 3 Hours: 1/2 inch to 6 inches
Additional sizes available in 1/4-inch increments from 1 to 6 inches
Length 6.56 linear feet
Application Interior or Exterior
Installation Wall
Certifications UL 2079
ASTM E1966, E119, E1399, E90 and C518
Options Terminations, Transitions, Additional Sizes, Single-Sided, Uncoated and Pick-Resistant Coatings available upon request
Movement Standard: +/-50% (Total 100%)
Also available in +/- 25% (Total 50%)
Warranty 1 year

Colors Adobe Tan
Adobe Tan
Aluminum Stone
Aluminum Stone
Buff
Buff
Anodized Aluminum
Anodized Aluminum
Black
Black
Bronze
Bronze
Champagne
Champagne
Charcoal
Charcoal
Dark Bronze
Dark Bronze
Dusty Rose
Dusty Rose
Gray
Gray
Ivory
Ivory
Light Bronze
Light Bronze
Limestone
Limestone
Precast White
Precast White
Rustic Brick
Rustic Brick
Sandstone
Sandstone
Off White
Off White
White
White

Order Guide

Use the table below to guide specification of available options. The part number components are indicated in BOLD ORANGE text.

PART NUMBER JOINT SIZE
at mean T° F
TOTAL MOVEMENT
EJN-FES1-050 1/2" (12mm) 4" (102mm)
EJN-FES1-075 3/4" (19mm) 4" (102mm)
EJN-FES1-100 1" (25mm) 4" (102mm)
EJN-FES1-200 2" (51mm) 4" (102mm)
EJN-FES1-300 3" (76mm) 4" (102mm)
EJN-FES1-400 4" (102mm) 4" (102mm)
EJN-FES2-050 1/2" (12mm) 4" (102mm)
EJN-FES2-075 3/4" (19mm) 4" (102mm)
EJN-FES2-100 1" (25mm) 4" (102mm)
EJN-FES2-200 2" (51mm) 4" (102mm)
EJN-FES2-300 3" (76mm) 4" (102mm)
EJN-FES2-400 4" (102mm) 4" (102mm)
EJN-FES2-500 5" (127mm) 4" (102mm)
EJN-FES2-600 6" (152mm) 4" (102mm)
EJN-FES3-050 1/2" (12mm) 4" (102mm)
EJN-FES3-075 3/4" (19mm) 4" (102mm)
EJN-FES3-100 1" (25mm) 4" (102mm)
EJN-FES3-200 2" (51mm) 4" (102mm)
EJN-FES3-300 3" (76mm) 4" (102mm)
EJN-FES3-400 4" (102mm) 4" (102mm)
EJN-FES3-500 5" (127mm) 4" (102mm)
EJN-FES3-600 6" (152mm) 4" (102mm)

Standard Movement of +/-50% (Total 100%), Also Available in +/-25% (Total 50%)

Additional sizes available in 1/4" increments from 1" and larger.

WARRANTY

NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.

Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at Nystrom's discretion. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.


For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.

Warranty Support

Videos

Coming soon.
Coming soon.
Description Model Shop Drawing CAD Revit/BIM Data Sheet 3-Part Specs LEED Installation Warranty
1-Hour
Fire-Rated Wall
EJN-FES1-050 PDF DWG PDF WORD PDF PDF PDF
1-Hour
Fire-Rated Wall
EJN-FES1-075 PDF DWG PDF WORD PDF PDF PDF
1-Hour
Fire-Rated Wall
EJN-FES1-100 PDF DWG PDF WORD PDF PDF PDF
1-Hour
Fire-Rated Wall
EJN-FES1-200 PDF DWG PDF WORD PDF PDF PDF
1-Hour
Fire-Rated Wall
EJN-FES1-300 PDF DWG PDF WORD PDF PDF PDF
1-Hour
Fire-Rated Wall
EJN-FES1-400 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-050 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-075 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-100 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-200 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-300 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-400 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-500 PDF DWG PDF WORD PDF PDF PDF
2-Hour
Fire-Rated Wall
EJN-FES2-600 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-050 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-075 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-100 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-200 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-300 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-400 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-500 PDF DWG PDF WORD PDF PDF PDF
3-Hour
Fire-Rated Wall
EJN-FES3-600 PDF DWG PDF WORD PDF PDF PDF

Specifications

Application:
Exterior Wall, Interior Wall & Ceiling, Open Air Structures (Stadiums), Parking Structures
Material Type:
Compression / Foam
Movement Type:
Seismic, Thermal