Seismic Exterior Plaza System Topping Slab Deck Application (TSS/TSSw)
Description
This Seismic Exterior Plaza System is a high performance, versatile completely watertight expansion joint system. Topping Slab Deck System accommodates variable system widths and heights in split slab construction.
Features
- Vehicular Rated - Parking Deck
- Horizontal Thermal Movement
- Seismic Movement
- Surface Mount
- Coordinating Corners
- ADA Compliant
Specifications
Model | TSS/TSSw |
Material | 6063-T6 Aluminum, Meets ASTM B209 |
Finish | Black |
Movement | Thermal: Horizontal Seismic |
Mounting | Surface |
Joint Sizes | 2 inches to 4 inches |
Length | 10 Linear Feet |
Application | Exterior |
Load | Vehicular and Pedestrian |
Installation | Floor or Deck |
Options | Fire barrier, Custom seal configurations and Cover plate available |
Warranty | 1 year |
Order Guide
Use the table below to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.
PART NUMBER | APPLICATION | JOINT SIZE at mean T°F |
EXPOSED SITE LINE | TOPPING SLAB HEIGHT | TOTAL MOVEMENT |
---|---|---|---|---|---|
EJN-TSS-200 | Deck to Deck | 2" (25mm) | 6" (152mm) | Varies | 3.75" (95mm) |
EJN-TSS-300 | Deck to Deck | 3" (76mm) | 6" (152mm) | Varies | 3.75" (95mm) |
EJN-TSS-400 | Deck to Deck | 4" (102mm) | 6" (152mm) | Varies | 3.75" (95mm) |
EJN-TSS-200W | Deck to Wall | 2" (25mm) | 5" (126mm) | Varies | 3.75" (95mm) |
EJN-TSS-300W | Deck to Wall | 3" (76mm) | 5" (126mm) | Varies | 3.75" (95mm) |
EJN-TSS-400W | Deck to Wall | 4" (102mm) | 5" (126mm) | Varies | 3.75" (95mm) |
WARRANTY
NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.
Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at the discretion of Nystrom. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.
For information on a warranty claim, please visit our Warranty Support section or call 800 547-2635.
Videos
Coming soon.Description | Model | Shop Drawing | CAD | Revit/BIM | Data Sheet | 3-Part Specs | LEED | Installation | Warranty |
---|---|---|---|---|---|---|---|---|---|
Deck to Deck | EJN-TSS-200 | DWG | WORD | ||||||
Deck to Deck | EJN-TSS-300 | DWG | WORD | ||||||
Deck to Deck | EJN-TSS-400 | DWG | WORD | ||||||
Deck to Wall | EJN-TSS-200W | DWG | WORD | ||||||
Deck to Wall | EJN-TSS-300W | DWG | WORD | ||||||
Deck to Wall | EJN-TSS-400W | DWG | WORD |