Sesimic Aluminum Wall & Ceiling System - Exterior Application (RJE/RJEw)
Nystrom Seismic Aluminum Exterior Wall System is a surface-mounted wall system designed to accommodate both thermal and multidirectional movement. The system provides an aesthetic, durable, and easy-to-install solution for exterior environments.
Features
- Weather-Resistant
- Engineered for Value
- Horizontal and Vertical Thermal Movement
- Seismic Movement with Lateral Shear
Specifications
Model | RJE/RJEw |
Material |
6063-T5 Aluminum, Meets ASTM B221 6061-T6 Aluminum, Meets ASTM B209 5052 H32 Aluminum, Meets ASTM B209 |
Finish | Mill |
Movement | Thermal: Horizontal and Vertical Seismic: Lateral Shear |
>Mounting | Surface |
Joint Size | 2 inches to 24 inches |
Length | 10 Linear Feet |
Application | Exterior |
Installation | Wall or Ceiling |
Options | Fire barrier, Additional Materials, Sizes and Finishes available upon request |
Warranty | 1 year |
Order Guide
Use the table belo to guide specification of available options. The part numbers are indicated in BOLD ORANGE text.
PART NUMBER | INSTALLATION | JOINT SIZE at mean T°F |
EXPOSED SIGHT LINE | TOTAL MOVEMENT |
---|---|---|---|---|
EJN-RJE-200 | Wall/Ceiling to Wall/Ceiling | 2" (51mm) | 7" (178mm) | 2" (51mm) |
EJN-RJE-400 | Wall/Ceiling to Wall/Ceiling | 4" (102mm) | 10" (255mm) | 4" (102mm) |
EJN-RJE-600 | Wall/Ceiling to Wall/Ceiling | 6" (152mm) | 12" (305mm) | 6" (152mm) |
EJN-RJE-800 | Wall/Ceiling to Wall/Ceiling | 8" (203mm) | 14" (356mm) | 8" (203mm) |
EJN-RJE-1000 | Wall/Ceiling to Wall/Ceiling | 10" (254mm) | 17" (432mm) | 10" (254mm) |
EJN-RJE-1200 | Wall/Ceiling to Wall/Ceiling | 12" (305mm) | 20" (508mm) | 12" (305mm) |
EJN-RJE-1400 | Wall/Ceiling to Wall/Ceiling | 14" (356mm) | 23" (584mm) | 14" (356mm) |
EJN-RJE-1600 | Wall/Ceiling to Wall/Ceiling | 16" (406mm) | 26" (660mm) | 16" (406mm) |
EJN-RJE-1800 | Wall/Ceiling to Wall/Ceiling | 18" (457mm) | 29" (737mm) | 18" (457mm) |
EJN-RJE-2000 | Wall/Ceiling to Wall/Ceiling | 20" (508mm) | 32" (813mm) | 20" (508mm) |
EJN-RJE-2400 | Wall/Ceiling to Wall/Ceiling | 24" (610mm) | 35" (889mm) | 24" (610mm) |
EJN-RJE-200W | Wall/Ceiling to Corner | 2" (51mm) | 4.5" (114mm) | 1" (25mm) |
EJN-RJE-400W | Wall/Ceiling to Corner | 4" (102mm) | 7" (178mm) | 2" (51mm) |
EJN-RJE-600W | Wall/Ceiling to Corner | 6" (152mm) | 9" (228mm) | 3" (76mm) |
EJN-RJE-800W | Wall/Ceiling to Corner | 8" (203mm) | 11" (280mm) | 4" (102mm) |
EJN-RJE-1000W | Wall/Ceiling to Corner | 10" (254mm) | 13.5" (343mm) | 5" (127mm) |
EJN-RJE-1200W | Wall/Ceiling to Corner | 12" (305mm) | 16" (406mm) | 6" (152mm) |
EJN-RJE-1400 | Wall/Ceiling to Wall/Ceiling | 14" (356mm) | 19" (483mm) | 7" (178mm) |
EJN-RJE-1600W | Wall/Ceiling to Wall/Ceiling | 16" (406mm) | 21" (533mm) | 8" (203mm) |
EJN-RJE-1800W | Wall/Ceiling to Wall/Ceiling | 18" (457mm) | 23.5" (597mm) | 9" (229mm) |
EJN-RJE-2000W | Wall/Ceiling to Wall/Ceiling | 20" (508mm) | 26" (660mm) | 10" (254mm) |
EJN-RJE-2400W | Wall/Ceiling to Wall/Ceiling | 24" (610mm) | 31" (787mm) | 12" (305mm) |
WARRANTY
NYSTROM warrants all Expansion Joint Systems to be free from manufacturing defects in materials, factory finishes, and workmanship for a period of one (1) year from the date of shipment.
Should a product fail to function in normal use within this period, Nystrom shall furnish a replacement or new part at the discretion of Nystrom. Failure to use product in methods consistent with Nystrom product manuals shall relieve Nystrom of any liability. Our liability under this warranty excludes installation or removal costs involved in the product replacement and excludes any responsibility for incidental or consequential damage of any nature.
For information on a warranty claim, please visit our Warranty Support section or call 800-547-2635.
Videos
Coming soon.Description | Model | Shop Drawing | CAD | Revit/BIM | Data Sheet | 3-Part Specs | LEED | Installation | Warranty |
---|---|---|---|---|---|---|---|---|---|
Wall/Ceiling to Wall/Ceiling | EJN-RJE-200 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-400 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-600 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-800 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-1000 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-1200 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-1400 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-1600 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-1800 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-2000 | DWG | |||||||
Wall/Ceiling to Wall/Ceiling | EJN-RJE-2400 | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-200W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-400W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-600W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-800W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-1000W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-1200W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-1400W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-1600W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-1800W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-2000W | DWG | |||||||
Wall/Ceiling to Corner | EJN-RJE-2400W | DWG |